By continuing use this site, you agree to the Terms & Conditions and our use of cookies.
Draeger X-Am 8000 Multi Gas Detector
Latest Products
Special Trend Products
Best Seller Products
Brands

Industrial Instrument Test And Calibration Services Company

Industries Safety Nigeria gives comprehensive Instrument Testing services as a feature of our Electrical Testing and Maintenance services. We perform Instrument Testing for mechanical plants, enormous business offices, and metropolitan power stations. We are free 10 hours every day, 6 days per week, and are the upkeep manager's best option for electrical testing, support, and fix.

Service Guarantee

Industries Safety Nigeria with a subsidiary company "Inclineworks International Limited" mission is to give the most elevated conceivable client care at a reasonable and moderate value that is helpful to both our self and our demographic. Each Instrumentation testing and calibration testing performed by Industries Safety Nigeria is upheld by our 100% consumer loyalty ensure. In the event that any instrument calibrated ever needs to recalibrate, Industries Safety Nigeria will readily recalibrate the device until it satisfies industry guidelines. Loose gear can prompt expensive blunders that may be hazardous to representative security. At Industries Safety Nigeria, we comprehend that our client's security is the main factor. Accordingly, we endeavor to guarantee that testing gear is entirely aligned as well as could be expected. Our promise is upheld by our year's palatable client assistance input and legit support by bringing customers back.

Calibration Services

For documentation and efficiency, we automate calibration procedures and record data. We can help you meet rigorous standards like the ISO 9000, FDA, EPA, and OSHA regulations.

Equipment Calibration, Repair, and Instrument Calibration:

  • On-site and in-shop calibration service
  • Pick-up and delivery service
  • ‘Rush – Next-On-Bench’ service available (call for details)
  • Returning equipment to within manufacturer’s specifications
  • Refurbishment services, returning your equipment to “like-new” conditions 
  • Replacement services, our wide range of affiliates, and vast resources will be at your disposal

Our expert technicians and field engineers in conjunction with our state-of-the-art equipment are able to calibrate, record, document, and in some cases revive obsolete equipment.

Our Outstanding On-Site Calibration Services Include:

  • Pressure Transducers
  • Differential Pressure
  • Ultra-sonic Flow Meters
  • Temperature Transducers
  • Gas Detectors
  • Level Transducers
  • RTD Wells

MSA Gas Detector Calibration Services

MSA Calibration Services company in nigeria

We calibrate all kinds of gas detectors which include an MSA gas detector; such as MSA Altair 4, MSA Altair 4x, MSA Altair 5, MSA Altair 5x, MSA Mono Gas, etc. We use the standard calibration gas to make sure all calibrations are pass with the above standard regulations as mentioned.

Draeger Gas Detector Calibration Services

Draeger Calibration Services Company in Nigeria

We also calibrate all kinds of gas detectors which include a Draeger gas detector; such as x-am 2500X-am 5000X-am 5600X-8000, etc. We use the standard calibration gas to make sure all calibrations are pass with the above standard regulations as mentioned.

Honeywell BW Gas Detector Calibration Services

Honeywell Calibration Services company in nigeria

Just as mentioned earlier, We also calibrate all kinds of Honeywell gas detectors which include a Honeywell BW Gas Alert Max XT II, BW Gas Alert Micro 5 - Multi-Gas Detector - Standard - IR, etc. We use the standard calibration gas to make sure all calibrations are pass with the above standard regulations as mentioned.

Other Gas Detector Calibration Services

Other Gas Detector Calibration Services

It might be boring to read when we list all kinds of gas detectors or all kinds of calibration services we render here at Industries Safety Nigeria. As we have listed or mentioned earlier, we also have other gas detectors or calibrations we do such as RKI Instrument gas detector, Evikon gas detector, and instrument test products, Kimessa Monoline gas detectors, and monitoring and control system.

You can always email us at Sales@safetynigeria.com or Call 09093333374, 08064338888.

Industries Safety Nigeria Instrument Calibration Specifications

Measurement Accuracy

Voltage DC

110.000 mV 0.025%+0.015% *

1.10000 V 0.025%+0.005% *

11.0000 V 0.025%+0.005% *

110.000 V 0.05%+0.005% *

300.00 V 0.05%+0.005% *

Voltage AC

20 to 40 Hz 2% + 10

40 to 500 Hz 0.5% + 5

500 to 1 kHz 2% + 10

1 kHz to 5 kHz 10% + 20

Ranges: 1.1000, 11.000, 110.00, 300V

Current DC

30.000 mA 0.01% + 0.015% *

110.00 mA 0.01% + 0.015% *

Resistance

11.000 Ω 0.05% + 50 mΩ

110.00 Ω 0.05% + 50 mΩ

1.1000 kΩ 0.05% + 500 mΩ

11.000 kΩ 0.1% + 10 Ω

Frequency

1.00 to 109.99 Hz 0.05 Hz

110.0 to 1099.9 Hz 0.5 Hz

1.100 to 10.999 kHz 5 Hz

11.00 to 50.00 kHz 50 Hz

Pressure

Accuracy: from 0.025% of range using any of 29 pressure modules

Modules available for differential, gauge, vacuum 

Absolute dual and high pressure

Note* (% of reading + % of full scale)

Source Accuracy

Voltage DC

110.000 mV 0.01%+0.005% *

1.10000 V 0.01%+0.005% *

15.0000 V 0.01%+0.005% *

Current DC

22.000 mA (Source) 0.01%+ 0.015% *

22.000 mA (Simulate) 0.02% + 0.03% *

Resistance

11.000 Ω 0.01% + 20 mΩ

110.00 Ω 0.01% + 40 mΩ

1.1000 kΩ 0.02% + 500 mΩ

11.000 kΩ 0.03% + 5Ω

Frequency

0.00 to 10.99 Hz 0.01 Hz

11.00 to 109.99 Hz 0.1 Hz

110.0 to 1099.9 Hz 0.1 Hz

1100 to 21999 Hz 2 Hz

22.000 to 50.000 kHz 5 Hz

Note* (% of reading + % of full scale)

RTDs and Thermocouples

Measure Accuracy:

10 Ω Cu (427):  2 °C

100 Ω Pt (3916): 0.3 °C

100 Ω Pt (3926): 0.3 °C

100 Ω Pt (385): 0.3 °C

200 Ω Pt (385): 0.3 °C

500 Ω Pt (385): 0.3 °C

1000 Ω Pt (385): 0.3 °C

120 Ω Ni (672): 0.3 °C

note: For 2-and 3-wire measurement, add 0.4°C

E: 0.3 °C

N: 0.5 °C

J: 0.3 °C

L: 0.3 °C

K: 0.3 °C

T: 0.3 °C

U: 0.3 °C

B: 0.9 °C

R: 1.0 °C

S: 0.9 °C

C: 0.6 °C

BP: 1.2 ºC

XK: 0.4 ºC

Note: Accuracy with external cold junction, for internal junction add 0.2°C

Source Accuracy

10 Ω Cu (427): 1 °C

100 Ω Pt (3916): 0.1 °C

100 Ω Pt (3926): 0.1 °C

100 Ω Pt (385): 0.1 °C

200 Ω Pt (385): 0.1 °C

500 Ω Pt (385): 0.1 °C

1000 Ω Pt (385): 0.1 °C

120 Ω Ni (672): 0.1 °C

Note: For 2-and 3-wire simulation, add 0.4 °C

E: 0.2 °C

N: 0.3 °C

J: 0.2 °C

L: 0.2 °C

K: 0.3 °C

T: 0.3 °C

U: 0.3 °C

B: 0.8 °C

R: 0.9 °C

S: 0.9 °C

C: 0.6 °C

BP: 0.5 ºC

XK: 0.4 ºC

Note: Accuracy with external cold junction, for internal junction add 0.2°C

Technical Data

Data Log Functions

Measure functions: Voltage, current, resistance, frequency, temperature, pressure

Reading rate: 1, 2, 5, 10, 20, 30, or 60 readings/minute

Maximum record length: 8000 readings (7980 for 30 or 60 readings/minute)

Ramp Functions

Source functions: Voltage, current, resistance, frequency, temperature

Rate: 4 steps/second

Trip detect: Continuity or voltage (continuity detection not available when sourcing current)

Loop Power Function

Voltage: Selectable, 24 V or 28 V

Accuracy: 5%

Maximum current: 22 mA, short circuit protected

Maximum input voltage: 30 V DC

Step Functions

Source Functions: Voltage, current, resistance, frequency, temperature

Environmental Specifications

Operating Temperature  

-10 °C to +50 °C -20 °C to +50 °C *

Storage Temperature  

-20 °C to +60 °C

Dust/water resistance 

Meets IP52, IEC 529

Operating Altitude 

2800 m

Note: * Except frequency and AC