- On sale!
an industrial safety & marine products distribution company
an industrial safety & marine products distribution company
The GX-6000 is an extremely versatile and powerful handheld gas monitor. In addition to the standard 4 gas sensors, there are 2 PID ranges, a Benzene specific PID, IR CO2 or % volume Methane sensors, and multiple special toxic sensors. The GX-6000 now features a Benzene-specific mode that uses one of the available smart sensor slots and a pre-filter tube holder.
The GX-6000 has 2 additional smart channels that accept PID, IR, or super toxic sensors. Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and a large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. The GX-6000 with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard. Four PID sensors are available, 10.0 eV, 10.6 eV (low or high range), and 11.7 eV. Any combination of two PID sensors can be installed.
Description
Simply put, the GX-6000 is a game-changer. This powerful hand-held PID gas monitor is capable of simultaneously monitoring up to 6 gases.
6 Gas Monitor,
PID gas monitor with simultaneous detection and display.
Dual VOC display with 2 PID sensors installed.
Monitor the standard 4 confined space gases which include combustibles, O2, CO, & H2S
GX-6000 has 2 additional smart channels that accept PID, IR, or super toxic sensors.
Safety Features
The GX-6000 is equipped with a strong internal sample pump in addition to advanced safety features.
Man-down alarm
Panic alarm
LED flashlight
Large auto rotating LCD display
PID Gas Monitor
The GX-6000 has 2 additional smart channels that accept PID, IR, or super toxic sensors. Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and a large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. The GX-6000 with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard. Choosing from the library is easy with a personalized favorites list of 30 commonly used VOCs as well as a list of 8 of the most recently used VOCs. A benzene-specific version is available using a pre-filter tube for detecting low levels of benzene. Four PID sensors are available, 10.0 eV, 10.6 eV (low or high range), and 11.7 eV. Any combination of two PID sensors can be installed.
30 of the commonly used VOCs.
8 of the most recently used VOCs.
Reliable and Durable
The GX-6000 is a rugged personal PID gas monitor built for the nastiest environments. Most noteworthy, it is equipped with a removable impact-resistant rubber boot.
Dust and water-resistant enclosure with an IP-67 rating.
5 bright LED lights on 3 sides of the instrument.
View Alarms easily from a variety of perspectives.
Vibration and loud audible alarm for immediate notification.
Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and a large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. The GX-6000 with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard. Choosing from the library is easy with a personalized favorites list of 30 commonly used VOCs as well as a list of 8 of the most recently used VOCs. A benzene-specific version is available using a pre-filter tube for detecting low levels of benzene.
Applications
Confined space entry
Hazmat response teams
Arson investigation
Remediation sites
Perimeter monitoring
Leak detection
Landfill monitoring
Wing tank entry
Gases & Detectable Ranges |
|||||
Gas |
Measuring Range |
Reading Increment |
Alarm Set Points |
Accuracy (whichever |
|
PID Sensors |
|||||
10.6 Lamp |
600 VOC’s |
0 – 50,000 ppb |
1 ppb: (< 5000 ppb) 10 ppb: (> 5,000 ppb) |
A1: 5,000 ppb |
± 10% of reading, ± 1 digit |
A2: 10,000 ppb |
|||||
0 – 6,000 ppm |
0.1 ppm: (< 600 ppm) 1 ppm: (> 600 ppm) |
A1: 400 ppm |
|||
A2: 1,000 ppm |
|||||
10.0 Lamp |
Benzene Specific |
0.1 – 50 ppm |
0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 50 ppm) |
No Alarms |
|
300 VOC’s |
0 – 100 ppm |
0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 100 ppm) |
A1: 5 ppm A2: 10 ppm |
||
11.7 Lamp |
High Voltage Lamp |
0 – 1000 ppm |
0.1 ppm |
A1: 400 ppm |
|
A2: 1,000 ppm |
|||||
Galvanic |
|||||
Oxygen (O2) |
0 – 40.0% Vol. |
0.1% Vol. |
A1: 19.5 Vol. |
± 0.5% O2 |
|
A2: 23.5 Vol. |
|||||
Electro-Chemical |
|||||
Carbon Monoxide (CO) |
0 – 500 ppm |
1 ppm |
A1: 25 ppm |
± 5% of reading or ± 5 ppm |
|
A2: 50 ppm |
|||||
TWA 25 ppm |
|||||
STEL 200 ppm |
|||||
Hydrogen Sulfide (H2S) |
0 – 100.0 ppm |
0.5 ppm |
A1: 5.0 ppm |
± 5% of reading or ± 2 ppm |
|
A2: 30.0 ppm |
|||||
TWA 1.0 ppm |
|||||
STEL 5.0 ppm |
|||||
Toxics (EC Sensors) |
|||||
Ammonia (NH3) |
0 – 400.0 ppm |
0.5 ppm |
A1: 25 ppm |
± 10% of reading or ± 5% of full scale |
|
A2: 50 ppm |
|||||
Chlorine (Cl2) |
0 – 10.00 ppm |
0.05 ppm |
A1: 0.5 ppm |
||
A2: 1.0 ppm |
|||||
Hydrogen Cyanide (HCN) |
0 – 15.0 ppm |
0.1 ppm |
A1: 5 ppm |
||
A2: 10 ppm |
|||||
Nitrogen Dioxide (NO2) |
0 – 20.00 ppm |
0.05 ppm |
A1: 3 ppm |
||
A2: 6 ppm |
|||||
Sulfur Dioxide (SO2) |
0 – 99.90 ppm |
A1: 2 ppm |
|||
A2: 5 ppm |
|||||
IR Sensors |
|||||
Carbon Dioxide (CO2) |
0 – 10,000 ppm |
20 ppm |
A1: 5,000 ppm |
± 5% of reading or ± 2% of full scale |
|
TWA 5,000 ppm |
|||||
0 – 10.00% Vol. |
0.02% |
A1: 0.50% Vol |
|||
A2: 3.00% Vol |
|||||
STEL 3.00% Vol |
|||||
TWA 0.50% Vol |
|||||
Methane (CH4) |
0 – 100% LEL 0 – 100% Vol. |
1% LEL/ 0.5% Vol |
A1: 10% LEL A2: 50% LEL |
||
Hydrocarbons |
0 – 100% LEL 0 – 30% Vol. |
||||
Catalytic |
|||||
Hydrocarbons (CH4, std) |
0 – 100% LEL |
1% LEL |
A1: 10%LEL |
± 5% of reading or ± 2% LEL |
|
A2: 50%LEL |
Common Specifications |
|||
Alarm Types |
Gas alarm |
Man-down |
Trouble |
Low and high adjustable |
1st – self-reset 2nd – latching |
Low flow Sensor connection Low battery Circuit error Calibration range
|
|
Sample Method |
Sample draw pump, flow rate 0.45 LPM, 50-foot sample range |
||
Display |
Digital LCD, auto backlight, peak bar display, auto display rotation, and customize the order of gases |
||
Audible Alarm |
95 dB at 1 ft. |
||
Languages |
English, Spanish, French, German, Italian, Japanese, Korean, Portuguese, Russian |
||
Continuous |
14 hours on a Lithium-ion battery pack. Complete recharge in 3 hours. 8 hours Alkaline battery pack (3 AA-size within each pack) |
||
Operating Temp. |
-4°F to 122°F (-20°C ~ +50℃), 0- 95% RH non condensing |
||
Dimensions |
2.6” W x 7.8” H x 2” D (H200 x W68 x D52 mm) 14 ounce (400g) (with lithium battery pack) |
||
Case Material |
Dust and water resistance with IP-67 approval (exclude sample hose and probe) |
||
Safety Design / Approvals |
Explosion-proof: IECEx, ATEX, TIIS, cCSAus Explosion class: Ex ia IIC T4 Ga Others: CE Marking |
||
Standard |
2 Smart sensors slots auto recognize sensor changes Library of over 600 VOC’s User-defined VOC list. Up to 30 frequently used Recent VOC list for last 8 selected gases Pump and circuit status indicators User & station ID selection menu Datalogging (interval, alarm trend, station, and user ID) Snap logging – on-demand data logging Demand zero / Auto zero BUMP and CAL expiration alarm Flashlight IrDA communication LEL sensor protection mode |
||
Standard |
• Rubber boot • Belt clip • Hand strap • Tapper nozzle• Probe with hydrophobic & dust filter 3’ Teflon lined hose• Benzene pre-filter tubes and holder (benzene versions) |
||
Optional |
• SDM-6000 calibration station • Bundles with instrument carrying case and accessories • Flexible probes • Up to 50-foot sample hoses • Filter set • IrDA cable
|
||
Warranty |
Two years of material (including sensors) and workmanship. One year for PID sensor (Two months for 11.7 eV lamp) |
product appraisal
This is the best product I ever got here in Nigeria, it actually served me perfectly well, all thanks to industries safety Nigeria for always supplying quality products