By continuing use this site, you agree to the Terms & Conditions and our use of cookies.
Reliwash Eye Wash 500ml - Including Eyebath Cap
  • On sale!
  • -₦600.00
  • New
₦17,675.00₦18,275.00Regular price Price
      Fluke 116 Digital HVAC Multimeter
      • Fluke 116 Digital HVAC Multimeter
      • Fluke 116 Digital HVAC Multimeter
      • Fluke 116 Digital HVAC Multimeter
      • Fluke 116 Digital HVAC Multimeter
      • Fluke 116 Digital HVAC Multimeter

      Fluke 116 Digital HVAC Multimeter

      Fluke
      Reviews(1)

      Key features

      • Digital multimeter designed specifically for HVAC professionals

      • Includes built-in thermometer to measure temperature from -40°C to 400°C (-40°F to 752°F)

      • Provides microamps to test flame sensors

      • Features low input impedance to helps prevent false readings due to ghost voltage

      • Presents a large white LED backlight for working in poorly lit areas

      Quantity :
      testtesttest

      Last time this product was added to a cart: 03/02/2023

      Allowed extensions: .pdf, .png, .jpeg, .gif, .jpg,
      • Secured
      • Fast Delivery
      • 7 days Return

      Buy Fluke 116 Digital HVAC Multimeter from Safety Nigeria, major supplier of safety equipment with fast delivery.

      Key features

      • Digital multimeter designed specifically for HVAC professionals

      • Includes built-in thermometer to measure temperature from -40°C to 400°C (-40°F to 752°F)

      • Provides microamps to test flame sensors

      • Features low input impedance to helps prevent false readings due to ghost voltage

      • Presents a large white LED backlight for working in poorly lit areas

      Product overview: Fluke 116 Digital HVAC Multimeter

      The Fluke 116 DMM provides the features you need to quickly troubleshoot HVAC equipment TheThe Fluke 116 was specifically designed for HVAC professionals. It has everything you need to quickly troubleshoot problems with HVAC equipment and flame sensors, including a built-in thermometer to measure temperatures up to 400°C (752°F) and microamps to test flame sensors. The Fluke 116 also measures resistance, continuity, frequency, and capacitance. And the large white LED backlight makes it easy to see results even in poorly lit areas.Fluke 116 multimeters are independently tested for safe use in CAT III 600 V environments.

      Other useful features:

      • Measures resistance, continuity, frequency, and capacitance

      • Provides Min/Max/Average to record signal fluctuations

      • Comes with a holster with probe holders for easy storage

      • Features a compact ergonomic design for one-handed operation

      • Fits into optional ToolPak™ magnetic hanger for hands-free operation

      • CAT III 600 V safety rated

      Specifications: Fluke 116 Digital HVAC Multimeter

      Specifications

      Maximum voltage between any terminal and earth ground

      600 V

      Surge protection

      6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2

      Display

      Digital: 6,000 counts, updates 4 per second

      Bar graph

      33 segments, updates 32 per second

      Operating temperature

      -10°C to + 50°C

      Storage temperature

      -40°C to + 60°C

      Battery type

      9 volt Alkaline, NEDA 1604A/ IEC 6LR61

      Battery life

      400 hours typical, without backlight

      Accuracy Specifications

      DC millivolts

      Range/resolution

      600.0 mV / 0.1 mV

      Accuracy

      ±([% of reading] + [counts]): 0.5% + 2

      DC volts

      Range/resolution

      6.000 V / 0.001 V

      60.00 V / 0.01 V

      600.00 V / 0.1 V

      Accuracy

      ±([% of reading] + [counts]): 0.5% + 2

      Auto volts

      Range/resolution

      600.0 V / 0.1 V

      Accuracy

      2.0% + 3 (DC, 45 Hz to 500 Hz)

      4.0% + 3 (500 Hz to 1 kHz)

      AC millivolts1 True RMS

      Range/resolution

      600.0 mV / 0.1 mV

      Accuracy

      1.0% + 3 (DC, 45 Hz to 500 Hz)

      2.0% + 3 (500 Hz to 1 kHz)

      AC volts1 True RMS

      Range/resolution

      6.000 V / 0.001 V

      60.00 V / 0.01 V

      600.0 V / 0.1 V

      Accuracy

      1.0% + 3 (DC, 45 Hz to 500 Hz)

      2.0% + 3 (500 Hz to 1 kHz)

      Continuity

      Range/resolution

      600 Ω / 1 Ω

      Accuracy

      Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of

      500 μs or longer.

      Ohms

      Range/resolution

      600.0 Ω / 0.1 Ω

      6.000 kΩ / 0.001 kΩ

      60.00 kΩ / 0.01 kΩ

      600.0 kΩ / 0.1 kΩ

      6.000 MΩ / 0.001 MΩ

      Accuracy

      0.9% + 1

      Range/Resolution

      40.00 MΩ / 0.01 MΩ

      Accuracy

      5% + 2

      Diode Test

      Range/resolution

      2.00 V / 0.001 V

      Accuracy

      0.9% + 2

      Capacitance

      Range/resolution

      1000 nF / 1 nF

      10.00 μF / 0.01 μF

      100.0 μF / 0.1 μF

      9999 μF / 1 μF

      100 μF to 1000 μF

      Accuracy

      1.9% + 2

      Range/resolution

      > 1000 μF

      Accuracy

      5% + 20%

      Lo-Z Capacitance

      Range

      1 nF to 500 μF

      Accuracy

      10% + 2 typical

      Temperature²

      (Type-K thermocouple)

      Range/resolution

      -40°C to 400°C / 0.1°C

      Accuracy

      1% + 10²

      Range/resolution

      -40°F to 752°F / 0.2°F

      Accuracy

      1% + 18²

      AC μA true-rms (45 Hz to 500 Hz)

      Range/resolution

      600.0 μA / 0.1 μA

      Accuracy

      1.5% + 3

      DC μamps

      Range/resolution

      600.0 μA / 0.1 μA

      Accuracy

      1.0% + 2

      Hz (V or A input)²

      Range/resolution

      99.99 Hz / 0.01 Hz

      999.9 Hz / 0.1 Hz

      9.999 kHz / 0.001 Hz

      50.00 kHz / 0.01 Hz

      Accuracy

      0.1% + 2

      1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.

      2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.

      3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.

      4. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.

      Mechanical and General Specifications

      Size

      167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)

      Weight

      550 g

      Warranty

      3 years

      Fluke

      Specific References

      New product
      Andrew U03/20/2020
      Fluke 116 Digital HVAC Multimeter

      fluke 116 digital multimeter

        Write your review
        Fluke 116 Digital HVAC Multimeter
        Fluke 116 Digital HVAC Multimeter

        Fluke 116 Digital HVAC Multimeter

        Allowed extensions: .pdf, .png, .jpeg, .gif, .jpg,