By continuing use this site, you agree to the Terms & Conditions and our use of cookies.
      Fluke 1587 Insulation Multimeter
      • Fluke 1587 Insulation Multimeter
      • Fluke 1587 Insulation Multimeter
      • Fluke 1587 Insulation Multimeter

      Fluke 1587 FC Insulation Multimeter

      Fluke
      Reviews(1)

      Key features

      • Safety first. Keep yourself out of harm's way by monitoring your test measurements remotely.

      • Prove your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone.

      • Quickly find problems by saving and comparing measurements over time on a wireless device.

      Quantity :
      testtesttest
      Allowed extensions: .pdf, .png, .jpeg, .gif, .jpg,
      • Secured
      • Fast Delivery
      • 7 days Return

      Key features

      • Safety first. Keep yourself out of harm's way by monitoring your test measurements remotely.

      • Prove your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone.

      • Quickly find problems by saving and comparing measurements over time on a wireless device.

      Product overview: Fluke 1587 FC Insulation Multimeter

      Keep yourself safe. Find hidden problems faster. Put the paperwork down.

      Fluke Connect + Fluke's 1587 FC Insulation Multimeter helps you identify tough problems, fix, and wirelessly communicate your work quickly and easily - all at a safe distance.

      Add diagnostics with Fluke Connect

      The Fluke 1587 FC is Fluke Connect-enabled so you can download the free Fluke Connect® Measurements app to your smartphone and gain additional functions, including:

      • Safety first. Keep yourself out of harm’s way by monitoring your test measurements remotely.

      • Prove your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone.

      • Quickly find problems by saving and comparing measurements over time on a wireless device.

      • PI/DAR timed ratio tests with TrendIt™ graphs to identify moisture and contaminated insulation problems faster

      • Memory storage through Fluke Connect that saves measurements to your phone or the cloud and eliminates the need to write down results. Reduces errors and saves data for historical tracking over time

      • Temperature compensation to establish accurate baselines and relevant historical comparisons

      • Historical tracking and trending of assets to identify insulation degradation over time and allow real-time decisions to be made in the field with Fluke Connect® Assets (sold separately)

      • Provides memory storage through Fluke Connect Measurements to eliminate the need to write down results

      • Includes live circuit detection to prevent insulation test if voltage >30 V is detected

      • Provides automated temperature compensation to establish accurate baselines

      • Supports historical tracking and asset trending of assets to identify degradation over time with Fluke Connect® Assets (sold separately)

      • Incorporates VFD low-pass filter for accurate variable frequency motor drive measurements

      • Includes auto-discharge of capacitive voltage for added user protection

      • Measures ac/dc voltage, dc millivolts, ac/dc milliamps, resistance, and continuity

      • Includes capacitance, diode test, temperature, min/max, frequency measurements and insulation test smoothing reading

      • Automatically powers off to save battery power

      • Comes with remote probe, test leads, alligator clips, K-type thermocouple, hard case, and three-year warranty.

      Specifications: Fluke 1587 FC Insulation Multimeter

      Electrical Specifications

      AC voltage measurement

      Range

      600.0 mV

      Resolution

      0.1 mV

      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

      ±(1% + 3)

      Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)

      ±(2% + 3)

      6.000 V

      Resolution

      0.001 V

      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

      ±(1% + 3)

      Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)

      ±(2% + 3)

      60.00 V

      Resolution

      0.01 V

      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

      ±(1% + 3)

      Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)

      ±(2% + 3)

      600.0 V

      Resolution

      0.1 V

      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

      ±(1% + 3)

      Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)

      ±(2% + 3)¹

      1000 V

      Resolution

      1 V

      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

      ±(2% + 3)

      Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)

      ±(2% + 3)¹

      ¹ 1 kHz bandwidth

      Low-Pass Filter Voltage 

      Range

      600.0 mV

      Resolution

      0.1 mV

      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

      ±(1% + 3)

      Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)

      +(2% + 3), -(6% - 3)

      6.000 V

      Resolution

      0.001 V

      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

      ±(1% + 3)

      Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)

      +(2% + 3), -(6% - 3)

      60.00 V

      Resolution

      0.01 V

      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

      ±(1% + 3)

      Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)

      +(2% + 3), -(6% - 3)

      600.0 V

      Resolution

      0.1 V

      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

      ±(1% + 3)

      Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)

      +(2% + 3), -(6% - 3)

      1000 V

      Resolution

      1 V

      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)

      ±(2% + 3)

      Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)

      +(2% + 3), -(6% - 3)

      DC Voltage Measurement

      Range

      Resolution

      Accuracy ±(% of Rdg + Counts)

      6.000 V dc

      0.001 V

      ±(0.09% + 2)

      60.00 V dc

      0.01 V

      ±(0.09% + 2)

      600.0 V dc

      0.1 V

      ±(0.09% + 2)

      1000 V dc

      1 V

      ±(0.09% + 2)

      Input impedance 

      10 MΩ (nominal), <100 pF

      Normal mode rejection ratio 

      >60 dB @ 50 Hz or 60 Hz

      Common mode rejection ratio 

      >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)

      Accuracies apply to ± 100% of range

      DC Millivolts Measurement

      Range

      Resolution

      Accuracy ±(% of Rdg + Counts)

      600.0 mVdc

      0.1 mV

      ±(0.1% + 1)

      DC and AC Current Measurement

      AC 45 Hz to 1000 Hz

      Range

      400 mA

      Resolution

      0.1 mA

      Accuracy ±(% of Rdg+Counts)

      ±(1.5% + 2)¹

      Burden voltage (Typical)

      2 mV/mA

      Range

      60 mA 

      Resolution

      0.01 mA 

      Accuracy ±(% of Rdg+Counts)

      ±(1.5% + 2)¹

      Burden voltage (Typical)

      2 mV/mA

      DC

      Range

      400 mA

      Resolution

      0.1 mA

      Accuracy ±(% of Rdg+Counts)

      ±(0.2% + 2)

      Burden voltage (Typical)

      2 mV/mA

      Range

      60 mA

      Resolution

      0.01 mA

      Accuracy ±(% of Rdg+Counts)

      ±(0.2% + 2)

      Burden voltage (Typical)

      2 mV/mA

      Overload

      600 mA for 2 minutes maximum

      Fuse protection for mA input

      0.44 mA, 1000 V, IR 10 kA

      AC conversion

      Inputs are ac-coupled and calibrated to the rms value of sine wave input

      Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.

      ¹ 1 kHz bandwidth

      Ohms Measurement

      Range

      Resolution

      Accuracy +(% of Rdg+Counts)¹

      600.0 Ω

      0.1 Ω

      ±(0.9% + 2)

      6.000 kΩ

      0.001 kΩ

      ±(0.9% + 2)

      60.00 kΩ

      0.01 kΩ

      ±(0.9% + 2)

      600.0 kΩ

      0.1 KΩ

      ±(0.9% + 2)

      6.000 MΩ

      0.001 MΩ

      ±(0.9% + 2)

      50.0 MΩ ²

      0.01 MΩ

      ±(1.5% + 3)

      Overload protection 

      1000 V rms or dc

      Open circuit test voltage 

      <8.0 V dc

      Short circuit current 

      <1.1 mA

      ¹ Accuracies apply from 0% to 100% of range

      ² Up to 80% relative humidity

      Diode Test

      Diode test indication

      Display voltage drop: 0.6 V at1.0 mA nominal test current:

      Accuracy

      ±(2% + 3)

      Continuity Test

      Continuity indication

      Continuous audible tone for testresistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 Ω

      Open circuit voltage

      <8.0 V

      Short circuit current

      1.0 mA typical

      Overload protection

      1000 V rms

      Response time

      >1 m sec

      Frequency Measurement

      Range

      Resolution

      Accuracy ±(% of Rdg+Counts)

      99.99 Hz 

      0.01 Hz 

      ±(0.1% + 1)

      999.9 Hz 

      0.1 Hz 

      ±(0.1% + 1)

      9.999 kHz 

      0.001 kHz 

      ±(0.1% + 1)

      99.99 kHz 

      0.01 kHz 

      ±(0.1% + 1)

      Frequency Counter Sensitivity

      600.0 mV ac 

      V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 

      100.0 mV 

      V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz

      150.0 mV 

      DC Trigger Levels¹ to 20 kHz²

      NA

      6.0 V 

      V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 

      1.0 V 

      V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz

      1.5 V 

      DC Trigger Levels¹ to 20 kHz²

      -400.0 mV and 2.5 V

      60.0 V 

      V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 

      10.0 V 

      V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz

      36.0 V 

      DC Trigger Levels¹ to 20 kHz²

      1.2 V and 4.0 V

      600.0 V 

      V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 

      100.0 V 

      V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz

      -

      DC Trigger Levels¹ to 20 kHz²

      12.0 V and 40.0 V

      1000.0 V 

      V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 

      300.0 V 

      V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz

      -

      DC Trigger Levels¹ to 20 kHz²

      12.0 V and 40.0 V

      ¹ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy

      ² Usable to 100 kHz with full scale input

      Capacitance

      Range 

      Resolution 

      Accuracy ±(% of Rdg+Counts)

      1000 nF 

      1 nF

      ±(1.2% + 2)

      10.00 μF 

      0.01 μF

      ±(1.2% + 2)

      100.0 μF 

      0.1 μF

      ±(1.2% ±90 counts)

      9999 μF 

      1 μF

      ±(1.2% ±90 counts)

      Temperature Measurement

      Range 

      Resolution 

      Accuracy ±(% of Rdg+Counts)¹

      -40 ° C to 537 ° C 

      0.1 °C 

      ±(1% + 10 counts)

      -40 ° F to 998 ° F 

      0.1 °F 

      ±(1% + 18 counts)

      ¹ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument

      Insulation Specifications

      Measurement range

      0.01 MΩ to 2 GΩ

      Test voltages

      50, 100, 250, 500, 1000 V

      Test voltage accuracy

      +20%, -0%

      Short-circuit test current

      1 mA nominal

      Auto discharge

      Discharge time <0.5 second for C = 1 μF or less

      Live circuit detection

      Inhibit test if terminal voltage > 30 V prior to initialization of test

      Maximum capacitive load

      Operable with up to 1 μF load

      Output Voltage

      50 V (0% to +20%)

      Display range

      0.01 to 6.00 MΩ

      Resolution

      0.01 MΩ

      Test current

      1 mA @ 50 kΩ

      Resistance accuracy ±(% of Rdg + Counts)

      ±(3% + 5 counts)

      Display range

      6.0 to 50.0 MΩ

      Resolution

      0.1 MΩ

      Test current

      1 mA @ 50 kΩ

      Resistance accuracy ±(% of Rdg + Counts)

      ±(3% + 5 counts)

      100 V (0% to +20%)

      Display range

      0.01 to 6.00 MΩ

      Resolution

      0.01 MΩ

      Test current

      1 mA @ 100 kΩ

      Resistance accuracy ±(% of Rdg + Counts)

      ±(3% + 5 counts)

      Display range

      6.0 to 60.0 MΩ

      Resolution

      0.1 MΩ

      Test current

      1 mA @ 100 kΩ

      Resistance accuracy ±(% of Rdg + Counts)

      ±(3% + 5 counts)

      Display range

      60 to 100 MΩ 

      Resolution

      1 MΩ

      Test current

      1 mA @ 100 kΩ

      Resistance accuracy ±(% of Rdg + Counts)

      ±(3% + 5 counts)

      250 V (0% to +20%)

      Display range

      0.1 to 60.0 MΩ 

      Resolution

      0.1 MΩ

      Test current

      1 mA @ 250 kΩ 

      Resistance accuracy ±(% of Rdg + Counts)

      ±(1.5% + 5 counts)

      Display range

      60 to 250 MΩ 

      Resolution

      1 MΩ

      Test current

      1 mA @ 250 kΩ 

      Resistance accuracy ±(% of Rdg + Counts)

      ±(1.5% + 5 counts)

      500 V (0% to +20%)

      Display range

      0.1 to 60.0 MΩ

      Resolution

      0.1 MΩ

      Test current

      1 mA @ 500 kΩ 

      Resistance accuracy ±(% of Rdg + Counts)

      ±(1.5% + 5 counts)

      Display range

      60 to 500 MΩ

      Resolution

      1 MΩ

      Test current

      1 mA @ 500 kΩ 

      Resistance accuracy ±(% of Rdg + Counts)

      ±(1.5% + 5 counts)

      1000 V (0% to +20%)

      Display range

      0.1 to 60.0 MΩ 

      Resolution

      0.1 MΩ

      Test current

      1 mA @ 1 MΩ

      Resistance accuracy ±(% of Rdg + Counts)

      ±(1.5% + 5 counts)

      Display range

      60 to 600 MΩ 

      Resolution

      1 MΩ

      Test current

      1 mA @ 1 MΩ

      Resistance accuracy ±(% of Rdg + Counts)

      ±(1.5% + 5 counts)

      Display range

      0.6 to 2.0 GΩ 

      Resolution

      100 MΩ 

      Test current

      1 mA @ 1 MΩ

      Resistance accuracy ±(% of Rdg + Counts)

      ±(10% + 3 counts)

      General Specifications

      Maximum voltage applied to any terminal and common

      1000 V

      Storage temperature

      -40 °C to 60 °C (-40 °F to 140 °F)

      Operating temperature

      -20 °C to 55 °C (-4 °F to 131 °F)

      Temperature coefficient

      0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F)

      Relative humidity

      Noncondensing

      0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F)

      0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F)

      0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F)

      Vibration

      Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument

      Radio frequency communication

      2.4 GHz ISM Band

      Radio frequency certification

      FCC: T68-FBLE, IC: 6627A-FBLE

      Electromagnetic Compatibility 

      International

      IEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A

      Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.

      Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes.  There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.

      Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected.

      Korea (KCC)

      Class A Equipment (Industrial Broadcasting & Communication Equipment)

      Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.

      USA (FCC)

      47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.

      Enclosure protection

      IEC 60529: IP40 (non-operating)

      Safety

      IEC 61010-1

      Pollution Degree 2

      IEC 61010-2-033

      CAT IV 600 V / CAT III 1000 V

      Batteries 

      Four AA batteries (NEDA 15A or IEC LR6)

      Battery life

      Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.

      Size (H x W x L)

      5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)

      Weight

      550 g (1.2 lb)

      Altitude

      Operating

      2000 m

      Storage

      12,000 m

      Over-range capability

      110% of range except for capacitance which is 100%

      Frequency overload protection

      <107 V Hz

      Fuse protection for mA input

      0.44A, 1000 V, IR 10 kA

      Fluke

      Specific References

      New product
      Andrew U03/20/2020
      Fluke 1587 FC Insulation Multimeter

      very good multimeter

        Write your review
        Fluke 1587 FC Insulation Multimeter
        Fluke 1587 Insulation Multimeter

        Fluke 1587 FC Insulation Multimeter

        Allowed extensions: .pdf, .png, .jpeg, .gif, .jpg,