an industrial safety & marine products distribution company
an industrial safety & marine products distribution company
Key features
General purpose digital multimeter for electrical and electronic testing
Ideal for quick verifications and field service
Presents a large white LED backlight for working in poorly lit areas
Measures AC and DC voltage to 600V
Measures AC and DC current to 10A (20 A overload for 30-seconds max)
Buy Fluke 115 True-RMS Digital Multimeter from Safety Nigeria, with fast delivery.
Key features
General purpose digital multimeter for electrical and electronic testing
Ideal for quick verifications and field service
Presents a large white LED backlight for working in poorly lit areas
Measures AC and DC voltage to 600V
Measures AC and DC current to 10A (20 A overload for 30-seconds max)
Product overview: Fluke 115 True-RMS Digital Multimeter
The Fluke 115 is the compact, general purpose troubleshooting tool for field service technicians
For general purpose electrical and electronic test requirements, the Fluke 115 True RMS digital multimeter provides the perfect answer. Its simple, one-handed operation and compact design meets the needs of a wide variety of field service technicians. It measures True RMS voltage and current with 6000 count resolution as well as resistance, continuity, frequency and capacitance for quick verifications.
Fluke 115 Digital Multimeters are independently tested for safe use in CAT III 600V environments.
Other useful features:
Measures resistance, continuity, frequency, and capacitance
Provides Min/Max/Average with elapsed time to record signal fluctuations
Comes with a holster with probe holders for easy storage
Features a compact ergonomic design for one-handed operation
Fits into optional ToolPak™ magnetic hanger for hands-free operation
CAT III 600 V safety rated
Specifications: Fluke 115 True-RMS Digital Multimeter
Specifications | |||
Maximum voltage between any terminal and earth ground | 600 V | ||
Surge protection | 6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2 | ||
Display | Digital: 6,000 counts, updates 4 per second | ||
Bar graph | 33 segments, updates 32 per second | ||
Operating temperature | -10°C to + 50°C | ||
Storage temperature | -40°C to + 60°C | ||
Battery type | 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 | ||
Battery life | 400 hours typical, without backlight | ||
Accuracy Specifications | |||
DC millivolts | Range/resolution | 600.0 mV / 0.1 mV | |
Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | ||
DC volts | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V |
|
Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | ||
AC millivolts1 True RMS | Range/resolution | 600.0 mV / 0.1 mV | |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
||
AC volts1 True RMS | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
|
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
||
Continuity | Range/resolution | 600 Ω / 1 Ω | |
Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer. |
||
Ohms | Range/resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ |
|
Accuracy | 0.9% + 1 | ||
Range/resolution | 40.00 MΩ / 0.01 MΩ | ||
Accuracy | 5% + 2 | ||
Diode test | Range/resolution | 2.00 V / 0.001 V | |
Accuracy | 0.9% + 2 | ||
Capacitance | Range/resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF |
|
Accuracy | 1.9% + 2 | ||
Range/resolution | > 1000 μF | ||
Accuracy | 5% + 20% | ||
Lo-Z capacitance | Range | 1 nF to 500 μF | |
Accuracy | 10% + 2 typical | ||
AC amps True RMS (45 Hz to 500Hz) |
Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
|
Accuracy | 1.5% + 3 20 A overload for 30-seconds max |
||
DC amps | Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
|
Accuracy | 1.0% + 3 20 A overload for 30-seconds max |
||
Hz (V or A input)2 | Range/resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.01 Hz 9.999 kHz / 0.001 kHz 50.00 kHz / 0.01 kHz |
|
Accuracy | 0.1% + 2 | ||
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. |
|||
Mechanical & General Specifications | |||
Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) | ||
Weight | 550 g | ||
Warranty | 3 years |