Key features
Insulation test voltages 500 V, 1000 V
Insulation test: 0.1 MΩ to 600 MΩ
Auto discharge of capacitive voltage
AC/DC Voltage
DC millivolts
AC/DC milliamps
Resistance (0.1 Ω to 50 MΩ)
Continuity
Three-year warranty
Remote probe, test leads, alligator clips
Rugged, utility hard case
Auto power off to save battery power
True RMS
Large display with backlight
Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
CAT III 1000V, CAT IV 600V measurement category
Accepts optional Fluke TPAKTM magnetic hanging system to free your hands for other work
Product overview: Fluke 1577 Insulation Multimeter
Two powerful tools in one
The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true RMS digital multimeter in a single, compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.
Whether you work on motors, generators, cables, or switch gear, the Fluke 1587/1577 Insulation Multimeters are ideally suited to help you with your tasks and at a cost that is far less than buying the two products.
Specifications: Fluke 1577 Insulation Multimeter
Specifications |
||
Voltage DC |
Maximum voltage |
1000 V |
Accuracy |
±(0.2%+2) |
|
Maximum resolution |
0.001 V |
|
Voltage AC |
Maximum voltage |
1000 V |
Accuracy |
±(2%+3) |
|
Maximum resolution |
0.1 mV |
|
Current DC |
Maximum amps |
400 mA |
Amps accuracy |
±(1.0%+2) |
|
Maximum resolution |
0.01 mA |
|
Current AC |
Maximum amps |
400 mA |
Amps accuracy |
±(2.0%+2)* |
|
Maximum resolution |
0.01 mA |
|
Resistance |
Maximum resistance |
50 MΩ |
Accuracy |
±(1.2%+2) |
|
maximum resolution |
0.1Ω |
|
Insulation Test |
||
Minimum test current @ 1kΩ/V |
1 mA |
|
Test voltages |
500, 1000 V |
|
Maximum resistance per test voltage |
50 V |
|
100 V |
||
250 V |
||
500 V |
||
1000 V |
600 MΩ |
|
Maximum resolution per test voltage |
50 V |
0.01 MΩ |
100 V |
0.01 MΩ |
|
250 V |
0.1 MΩ |
|
500 V |
0.1 MΩ |
|
1000 V |
0.1 MΩ |
|
Accuracy per test voltage |
50 V |
±(3% + 5) |
100 V |
±(3% + 5) |
|
250 V |
±(1.5% + 5) |
|
500 V |
±(2.0% + 5) |
|
1000 V |
±(2.0% + 5) |
|
Environmental Specifications |
||
Operating temperature |
–20°C to +55°C |
|
Storage temperature |
-40°C to +60°C |
|
Humidity (without condensation) |
0% - 95% (10°C – 30°C) 0% - 75% (30°C – 40°C) 0% - 40% (40°C – 55°C) |
|
Operating altitude |
2000 m |
|
Safety Specifications |
||
Overvoltage category |
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V |
|
Agency approvals |
2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V |
|
Mechanical and General Specifications |
||
Size |
203 x 100 x 50 mm (with holster) |
|
Weight |
624 g |
|
Warranty |
3 years |
|
Battery life alkaline |
Meter use |
1000 hours |
Insulation test use |
Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. |
|
IP rating |
IP40 |
Fluke 1577 Insulation Multimeter