      Fluke 1503 Insulation Resistance Tester Meter

      Fluke
      Reviews(1)

      Key features

      • A rugged, compact insulation resistance tester for residential and commercial electricians

      • Performs insulation tests from 0.01 MΩ to 2000 MΩ

      • Offers two insulation test voltages: 500 V and 1000 V

      • Includes live circuit detection to prevent insulation test if voltage >30 V is detected

      • Measures resistance from 0.01 Ω to 20.00 kΩ

      Quantity :
      testtesttest
      Allowed extensions: .pdf, .png, .jpeg, .gif, .jpg,
      • Secured
      • Fast Delivery
      • 7 days Return

      Buy Fluke 1503 Insulation Resistance Tester Meter from safety Nigeria, your online supplier of flukes with fast delivery. 

      Key features

      • A rugged, compact insulation resistance tester for residential and commercial electricians

      • Performs insulation tests from 0.01 MΩ to 2000 MΩ

      • Offers two insulation test voltages: 500 V and 1000 V

      • Includes live circuit detection to prevent insulation test if voltage >30 V is detected

      • Measures resistance from 0.01 Ω to 20.00 kΩ

      Product overview: Fluke 1503 Insulation Resistance Meter

      Fluke 1503 Insulation Resistance Tester handles all the basic insulation testing needs

      The Fluke 1503 is a great choice for basic residential and commercial electrical insulation testing. This rugged, compact tool fits in the palm of your hand. The 1503 is the same form factor as the Fluke 1507 but with a few less features. You can count on it to handle the most common tests at a most affordable price. Additional features, like the remote probe, reduce the time needed to perform repetitive testing.

      Other useful capabilities:

      • Measures AC/DC voltage from 0.1 V to 600 V

      • Includes auto-discharge of capacitive voltage for added user protection

      • Provides lo-ohms earth-bond continuity (200 mA)

      • Simplifies repetitive or hard-to-reach testing with the remote test probe

      • Saves battery power with auto power off

      • Presents results on a large, backlit display

      • Features CAT IV 600 V overvoltage category rating

      • Comes with remote probe, test leads, test probes, alligator clips, and one-year warranty

      • Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work

      • Runs on four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests

      Specifications: Fluke 1503 Insulation Resistance Meter

      AC/DC Voltage Measurement

      Accuracy

      Range

      600.0 V

      Resolution

      0.1 V

      50 Hz to 400 Hz ±(% of Rdg + Digits)

      ±(2% + 3)

      Input impedance

      3 MΩ (nominal), < 100 pF

      Common mode rejection ratio (1 kΩ unbalanced)

      > 60 dB at DC, 50 or 60 Hz

      Overload protection

      600 V rms or DC

      Earth Bond Resistance Measurement

      Range/Resolution

      20.00 Ω

      0.01 Ω

      200.0 Ω

      0.1 Ω

      2000 Ω

      1.0 Ω

      20.00 kΩ

      0.01 kΩ

      Accuracy

      ±(1.5% + 3)

      Overload protection

      2 V rms or DC

      Open circuit test voltage

      > 4.0 V, < 8 V

      Short circuit current

      > 200.0 mA

      Insulation Specifications

      Measurement range

      0.01 MΩ to 2000 MΩ

      Test voltage

      500 V, 1000 V

      Test voltage accuracy

      + 20%, - 0%

      Short circuit current

      1 mA nominal

      Auto discharge

      Discharge time < 0.5 second for C = 1 µF or less

      Live circuit indicator

      Inhibit test if terminal voltage > 30 V prior to initialization of test

      Maximum capacitive load

      Operable with up to 1 µF load

      Measure accuracy

      500 V

      ±(1.5% + 5)

      1000 V

      ±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ

      General Specifications

      Maximum voltage applied to any terminal:

      600 V AC rms or DC

      Storage temperature

      -40°C to 60°C (-40°F to 140°F)

      Operating temperature

      -20°C to 55°C (-4°F to 131°F)

      Temperature coefficient

      0.05 x (specified accuracy) per °C for temperatures < 18°C or > 28°C (< 64°F or > 82°F)

      Relative humidity

      0% to 95% @ 10°C to 30°C (50°F to 86°F)

      0% to 75% @ 30°C to 40°C (86°F to 104°F)

      0% to 40% @ 40°C to 55°C (104°F to 131°F)

      Vibration

      Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument

      Shock

      1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)

      Electromagnetic compatibility

      In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997)

      Safety

      Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)

      Certifications

      CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition

      Batteries

      Four AA batteries (NEDA 15A or IEC LR6)

      Battery llife

      Insulation test use:

      Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.

      Resistance measurements:

      Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.

      Size (H x W x L)

      5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)

      Weight

      550 g (1.2 lb)

      IP rating

      IP40

      Altitude

      Operating

      2000 m CAT IV 600 V, 3000 m CAT III 600 V

      Non-operating (storage)

      12,000 m

      Over-range capability

      110% of range

      Included accessories

      TL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe

      Fluke

      Specific References

      New product
      Andrew U03/20/2020
      Fluke 1503 Insulation Resistance Tester Meter

      true resistance tester

        Write your review
        Fluke 1503 Insulation Resistance Tester Meter
        Fluke 1503 Insulation Resistance Tester

        Fluke 1503 Insulation Resistance Tester Meter

        Allowed extensions: .pdf, .png, .jpeg, .gif, .jpg,