Fluke 376 True RMS AC/DC Clamp Meter with iFlex

Fluke 376 True RMS AC/DC Clamp Meter with iFlex

No reward points for this product.


  • iFlex® Flexible Current Probe expands the measurement range to 2500 A AC

  • CAT IV 600 V, CAT III 1000 V

  • True RMS AC voltage and current for accurate measurements on non-linear signals

  • Min, max, average and Inrush recording to capture variations automatically

More details...

0

Availability : Available

Add to wishlist

Call For Price

  • iFlex® Flexible Current Probe expands the measurement range to 2500 A AC

  • CAT IV 600 V, CAT III 1000 V

  • True RMS AC voltage and current for accurate measurements on non-linear signals

  • Min, max, average and Inrush recording to capture variations automatically

  • Integrated low pass filter and state-of-the-art signal processing allows for use in noisy electrical environments while providing stable readings

  • Proprietary Inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it

  • Ergonomic design fits in your hand and can be used while wearing protective equipment

  • Large, easy to read backlight display automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement

  • Three-year warranty

  • Soft Carrying Case

Electrical Specifications

AC Current via Jaw

Range

374 and 375
376

600.0 A

999.9 A

Resolution

0.1 A

Accuracy

2% ± 5 digits (10-100 Hz)

2.5% ± 5 digits (100-500 Hz)

Crest Factor (50/60 Hz)

3 @ 500 A (375 and 376 only)

2.5 @ 600 A 

1.42 @1000 A (376 only) 

Add 2% for C.F. > 2

AC Current via Flexible Current Probe

Range

2500 A

Resolution

374 and 375

0.1 A (≤ 600 A)

1 A (≤ 2500 A)

376

0.1 A (≤ 999.9 A)

1 A (≤ 2500 A)

Accuracy

3% ±5 digits (5 – 500 Hz)

Crest Factor (50/60Hz)

3.0 at 1100 A (375 and 376 only)

2.5 at 1400 A

1.42 at 2500 A

Add 2% for C.F. > 2

Distance from Optimum

i2500-10 Flex

i2500-18 Flex

Error

Flexible current probe

A

0.5 in (12.7 mm)

1.4 in (35.6 mm)

± 0.5%

B

0.8 in (20.3 mm)

2.0 in (50.8 mm)

± 1.0%

C

1.4 in (35.6 mm)

2.5 in (63.5 mm)

± 2.0%

Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.

DC Current

Range

374 and 375
376

600.0 A

999.9 A

Resolution

0.1 A

Accuracy

2% ± 5 digits

AC Voltage

Range

374 and 375
376

600.0 V

1000 V

Resolution

374 and 375
376

0.1 V

0.1 V (≤ 600.0 V)

1 V (≤ 1000 V)

Accuracy

1.5% ± 5 digits (20 – 500 Hz)

DC Voltage

Range

374 and 375
376

600.0 V

1000 V

Resolution

374 and 375
376

0.1 V

0.1 V (≤ 600.0 V)

1 V (≤ 1000 V)

Accuracy

1% ± 5 digits

mV dc

Range

375 and 376

500.0 mV

Resolution

0.1 mV

Accuracy

1% ± 5 digits

Frequency via Jaw

Range

375 and 376

5.0 - 500.0 Hz

Resolution

0.1 Hz

Accuracy

0.5% ± 5 digits

Trigger Level

5 – 10 Hz, ≥10 A

10 – 100 Hz, ≥5 A

100 – 500 Hz, ≥10 A

Frequency via Flexible Current Probe

Range

375 and 376

5.0 - 500.0 Hz

Resolution

0.1 Hz

Accuracy

0.5% ± 5 digits

Trigger Level

5 – 20 Hz, ≥ 25 A

20 – 100 Hz, ≥ 20 A

100 – 500 Hz, ≥ 25 A

Resistance

Range

374
375 and 376

6000 Ω

60 kΩ

Resolution

374

0.1 Ω (≤ 600 Ω)

1 Ω (≤ 6000 Ω)

375 and 376

0.1 Ω (≤ 600 Ω)

1 Ω (≤ 6000 Ω)

10 Ω (≤ 60 kΩ)

Accuracy

1% ± 5 digits

Capacitance

Range

1000 μF

Resolution

0.1 μF (≤ 100 μF)

1 μ F (≤ 1000 μF)

Accuracy

1% ± 4 digits

Mechanical Specifications

Size (L x W x H)

246 mm x 83 m x 43 mm

Weight

388 g

Jaw Opening

34 mm

Flexible Current Probe Diameter

7.5 mm

Flexible Current Probe Cable Length

(head to electronics connector)

1.8 m

Environmental Specifications

Operating Temperature

10°C – +50°C

Storage Temp

-40°C – +60°C

Operating Humidity

Non condensing (< 10 –°C)

≤ 90% RH (at 10°C – 30°C)

≤ 75% RH (at 30°C – 40°C)

≤ 45% RH (at 40°C – 50°C)

Operating Altitude

3000 meters

Storage Altitude

12,000 meters

EMC

EN 61326-1:2006

Temperature Coefficients

Add 0.1 x specified accuracy for each

degree C above 28°C or below 18°C

Safety Specifications

Safety Compliance

CAN/CSA-C22.2 No. 61010-1-04

ANSI/UL 61010-1:2004

ANSI/ISA-61010-1 (82.02.01):2004

EN/IEC 61010-1:2001 to

1000V Measurement Category (CAT) III

600V Measurement Category (CAT) IV

Pollution Degree 2

EN/IEC 61010-2-032:2002

EN/IEC 61010-031:2002+A1:2008

Agency Approvals

  

Batteries

2 AA, NEDA 15A, IEC LR6

Write your review

Fluke 376 True RMS AC/DC Clamp Meter with iFlex

Fluke 376 True RMS AC/DC Clamp Meter with iFlex

  • iFlex® Flexible Current Probe expands the measurement range to 2500 A AC

  • CAT IV 600 V, CAT III 1000 V

  • True RMS AC voltage and current for accurate measurements on non-linear signals

  • Min, max, average and Inrush recording to capture variations automatically

Write your review

Path: > > > Fluke 376 True RMS AC/DC Clamp Meter with iFlex

30 other products in the same category :