  • Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V
  • Insulation test: 0.01 MΩ to 2.0 GΩ
  • Auto discharge of capacitive voltage
  • Insulation test smoothing reading
  • Frequency
  • Capacitance
  • Diode test
  • Temperature
  • Min/Max
  • Low pass filter (for work on VSD's)
  • AC/DC Voltage
  • DC millivolts
  • AC/DC milliamps
  • Resistance (0.1 Ω to 50 MΩ)

More details...

  • Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V
  • Insulation test: 0.01 MΩ to 2.0 GΩ
  • Auto discharge of capacitive voltage
  • Insulation test smoothing reading
  • Frequency
  • Capacitance
  • Diode test
  • Temperature
  • Min/Max
  • Low pass filter (for work on VSD's)
  • AC/DC Voltage
  • DC millivolts
  • AC/DC milliamps
  • Resistance (0.1 Ω to 50 MΩ)
  • Continuity
  • Three-year warranty
  • Remote probe, test leads, alligator clips
  • K-type thermocouple
  • Rugged, utility hard case
  • Auto power off to save battery power
  • True RMS
  • Large display with backlight
  • Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
  • CAT III 1000V, CAT IV 600V measurement category
  • Accepts optional Fluke TPAKTM magnetic hanging system to free your hands for other work

Specifications
Voltage DCMaximum voltage1000 V
Accuracy±(0.09% + 2)
Maximum resolution0.001 V
Voltage ACMaximum voltage1000 V
Accuracy±(2% + 3)
AC bandwidth5 kHz1
1. with low pass filter; 3 db @ 800 Hz
Maximum resolution0.1 mV
Current DCMaximum amps400 mA
Amps accuracy±(0.2% + 2)
Maximum resolution0.01 mA
Current ACMaximum amps400 mA
Amps accuracy±(1.5% + 2)2
2. 1 kHz bandwidth
Maximum resolution0.01 mA
ResistanceMaximum resistance50 MΩ
Accuracy±(0.9% + 2)
Maximum resolution0.1 Ω
CapacitanceMaximum capacitance9,999 µF
Accuracy±(1.2% + 2)
Maximum resolution1 nF
FrequencyMaximum frequency100 kHz
Accuracy±(0.1% + 1)
Maximum resolution0.01 Hz
Temperature Measurement-40.0°C to 537°C
-40.0°F to 998°F excluding probe
Diode testRange/Resolution6 V / 1 mV
Accuracy±(2% + 1)
Insulation Test
Minimum test current @ 1kΩ/V1 mA
Test Voltages50, 100, 250, 500, 1000 V
Maximum resistance per test voltage50 V 
100 V 
250 V 
500 V 
1000 V2 GΩ
Maximum resolution per test voltage50 V0.01 MΩ
100 V0.01 MΩ
250 V0.1 MΩ
500 V0.1 MΩ
1000 V0.1 MΩ
Accuracy per test voltage50 V±(3% + 5)
100 V±(3% + 5)
250 V±(1.5% + 5)
500 V±(1.5% + 5)
1000 V±(1.5% + 5) to 600 MΩ, ±(10% + 3) above 600 MΩ
Environmental Specifications
Operating temperature–20°C to +55°C
Storage temperature-40°C to +60°C
Humidity (without condensation)0% - 95% (10°C – 30°C)
0% - 75% (30°C – 40°C)
0% - 40% (40°C – 55°C)
Operating altitude2000 m
Safety Specifications
Overvoltage categoryComplies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V
Agency approvals2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V
Mechanical and General Specifications
Size203 x 100 x 50 mm (with holster)
Weight624 g
Warranty3 years
Battery life alkalineMeter use1000 hours
Insulation test u6seMeter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
IP ratingIP40

Write your review

Fluke 1587 Insulation Multimeter

Fluke 1587 Insulation Multimeter

  • Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V
  • Insulation test: 0.01 MΩ to 2.0 GΩ
  • Auto discharge of capacitive voltage
  • Insulation test smoothing reading
  • Frequency
  • Capacitance
  • Diode test
  • Temperature
  • Min/Max
  • Low pass filter (for work on VSD's)
  • AC/DC Voltage
  • DC millivolts
  • AC/DC milliamps
  • Resistance (0.1 Ω to 50 MΩ)