Features and benefits

  • 600 A ac current measurement with fixed jaw
  • 600 VAC and DC voltage measurement
  • State of the art signal processing allows for use in noisy electrical environments while providing stable readings
  • CAT IV 300 V, CAT III 600 V
  • True RMS AC voltage and current for accurate measurements on non-linear signals

More details...

Features and benefits

  • 600 A ac current measurement with fixed jaw
  • 600 VAC and DC voltage measurement
  • State of the art signal processing allows for use in noisy electrical environments while providing stable readings
  • CAT IV 300 V, CAT III 600 V
  • True RMS AC voltage and current for accurate measurements on non-linear signals
  • Large, easy to read backlight display automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
  • Three-year warranty
  • Soft carrying case

Electrical Specifications
AC Current
Range600.0 A
Resolution0.1 A
Accuracy2 % ± 5 digits (48 – 62 Hz)
Crest Factor (50/60 Hz)2.5 @ 600 A
AC Voltage
Range600.0 A
Resolution0.1 A
Accuracy1.0 % ± 5 digits (48 – 62 Hz)
DC Voltage
Range600.0 A
Resolution0.1 A
Accuracy1 % ± 5 digits
Resistance
Range600.0 Ω/6000 Ω
Resolution0.1 Ω/1 Ω
Accuracy1 % ± 5 digits
Continuity Beeper30 Ω
Capacitance
Range10.0 – 100.0 μF / 1000 μF
Resolution0.1 μF/1 μF
Accuracy1.9 % ± 2 digits
Mechanical Specifications
Size (L x W x H)232 mm x 85 mm x 45 mm
Weight370 g
Environmental Specifications
Operating Temperature-10 °C to +50 °C
Storage Temp-40 °C to +60 °C
Operating HumidityNon condensing (< 10 °C)
≤ 90 % RH (at 10 °C to 30 °C)
≤ 75 % RH (at 30 °C to 40 °C)
≤ 45 % RH (at 40 °C to 50 °C)
(Without Condensation)
Operating Altitude3000 meters
Storage Altitude12,000 meters
EMI, EMCMeets all applicable requirements in EN61326-1:2006
Temperature CoefficientsAdd 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C
Safety ComplianceANSI/ISA S82.02.01:2004
CAN/CSA-C22.2 No. 61010-1-04
IEC/EN 61010-1:2001, 600V CAT III, 300V CAT IV
Pollution Degree 2
EN/IEC 61010-2-32:2002
EN/IEC 61010-031:2002/A1:2008
Agency Approvals  
Batteries2 AA, NEDA 15A, IEC LR6

Write your review

Fluke 373 True RMS AC Clamp Meter

Fluke 373 True RMS AC Clamp Meter

Features and benefits

  • 600 A ac current measurement with fixed jaw
  • 600 VAC and DC voltage measurement
  • State of the art signal processing allows for use in noisy electrical environments while providing stable readings
  • CAT IV 300 V, CAT III 600 V
  • True RMS AC voltage and current for accurate measurements on non-linear signals

Write your review

30 other products in the same category :