Measuring Equipments

Viewed products

Buy up to 10 and get 10% discount

Fluke-116-Digital-Multimeter

No reward points for this product.


  • Built-in thermometer for HVAC applications

  • Microamp to test flame sensors

  • Low input impedance: helps prevent false readings due to ghost voltage

  • Large white LED backlight to work in poorly lit areas

  • Resistance, continuity, frequency and capacitance

More details...

  • Built-in thermometer for HVAC applications

  • Microamps to test flame sensors

  • Low input impedance: helps prevent false readings due to ghost voltage

  • Large white LED backlight to work in poorly lit areas

  • Resistance, continuity, frequency and capacitance

  • Min/Max/Average with elapsed time to record signal fluctuations

  • Compact ergonomic design for one-handed operation

  • Compatible with optional magnetic hanger (ToolPak™)

  • CAT III 600 V safety rated

Specifications

Maximum voltage between any terminal and earth ground

600 V

Surge protection

6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2

Display

Digital: 6,000 counts, updates 4 per second

Bar graph

33 segments, updates 32 per second

Operating temperature

-10°C to + 50°C

Storage temperature

-40°C to + 60°C

Battery type

9 volt Alkaline, NEDA 1604A/ IEC 6LR61

Battery life

400 hours typical, without backlight

Accuracy Specifications

DC millivolts

Range/resolution

600.0 mV / 0.1 mV

Accuracy

±([% of reading] + [counts]): 0.5% + 2

DC volts

Range/resolution

6.000 V / 0.001 V

60.00 V / 0.01 V

600.00 V / 0.1 V

Accuracy

±([% of reading] + [counts]): 0.5% + 2

Auto volts

Range/resolution

600.0 V / 0.1 V

Accuracy

2.0% + 3 (DC, 45 Hz to 500 Hz)

4.0% + 3 (500 Hz to 1 kHz)

AC millivolts1 True RMS

Range/resolution

600.0 mV / 0.1 mV

Accuracy

1.0% + 3 (DC, 45 Hz to 500 Hz)

2.0% + 3 (500 Hz to 1 kHz)

AC volts1 True RMS

Range/resolution

6.000 V / 0.001 V

60.00 V / 0.01 V

600.0 V / 0.1 V

Accuracy

1.0% + 3 (DC, 45 Hz to 500 Hz)

2.0% + 3 (500 Hz to 1 kHz)

Continuity

Range/resolution

600 Ω / 1 Ω

Accuracy

Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of

500 μs or longer.

Ohms

Range/resolution

600.0 Ω / 0.1 Ω

6.000 kΩ / 0.001 kΩ

60.00 kΩ / 0.01 kΩ

600.0 kΩ / 0.1 kΩ

6.000 MΩ / 0.001 MΩ

Accuracy

0.9% + 1

Range/Resolution

40.00 MΩ / 0.01 MΩ

Accuracy

5% + 2

Diode Test

Range/resolution

2.00 V / 0.001 V

Accuracy

0.9% + 2

Capacitance

Range/resolution

1000 nF / 1 nF

10.00 μF / 0.01 μF

100.0 μF / 0.1 μF

9999 μF / 1 μF

100 μF to 1000 μF

Accuracy

1.9% + 2

Range/resolution

> 1000 μF

Accuracy

5% + 20%

Lo-Z Capacitance

Range

1 nF to 500 μF

Accuracy

10% + 2 typical

Temperature²

(Type-K thermocouple)

Range/resolution

-40°C to 400°C / 0.1°C

Accuracy

1% + 10²

Range/resolution

-40°F to 752°F / 0.2°F

Accuracy

1% + 18²

AC μA true-rms (45 Hz to 500 Hz)

Range/resolution

600.0 μA / 0.1 μA

Accuracy

1.5% + 3

DC μamps

Range/resolution

600.0 μA / 0.1 μA

Accuracy

1.0% + 2

Hz (V or A input)²

Range/resolution

99.99 Hz / 0.01 Hz

999.99 Hz / 0.1 Hz

9.999 Hz / 0.001 Hz

50.00 Hz / 0.01 Hz

Accuracy

0.1% + 2

1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.

2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.

3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.

4. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.

Mechanical and General Specifications

Size

167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)

Weight

550 g

Warranty

3 years

Write your review

Fluke-116-Digital-Multimeter

Fluke-116-Digital-Multimeter

  • Built-in thermometer for HVAC applications

  • Microamp to test flame sensors

  • Low input impedance: helps prevent false readings due to ghost voltage

  • Large white LED backlight to work in poorly lit areas

  • Resistance, continuity, frequency and capacitance

Write your review

30 other products in the same category :